7 reasons for the noise of the mixer
1. Difficulties or insufficiency in oil absorption caused by filter clogging; cleaning or replacing the filter element.
2. The working oil is not satisfactory or the viscosity of the oil is too high; replace the low viscosity hydraulic oil.
3. The fluid level of the fuel tank is too low and the air on the oil surface is sucked into the pump; add the same number of hydraulic oil.
4. Intake or blockage of the suction line; check tightly, do not inhale air.
5. The rigidity of the mounting bracket of the pump is insufficient, and vibration and noise may occur during operation;
6. The connection between the input flange and the universal joint shaft, the connection angle between the universal joint shaft and the power take-off device is too large and loose, and noise will be generated; check the tightening.
7. There is a bonded concrete stock in the tank and it must be cleaned.
In general, if your mixer is noisy, you should carefully check the causes and take appropriate measures to prevent minor problems from becoming a major problem.
Urea`s nitrogen content is the highest among all the solid fertilizer,as a type of a neutral, available fertilizer.It can be used either alone or as material for varieties of compound fertilizers.No harmful substances are left in the soil and there is no adverse effect of long-term application.
Urea N46% |
|
Granular Size |
2-4mm |
Prilled Size |
0.85-2mm |
Color |
Pure White |
Nitrogen |
46% min |
Moisture |
1% max |
Biuret |
1% max |
Radiation |
Non-radiactive |
Free Ammonia |
160pxt ppm max |
Urea is usually used as based fertilizer & topdressing,sometimes as seed fertilizer.
1. Urea can only be absorbed by plants after hydrolyzed,prevent it lose with moisture before that
2. It needs to be applied 4-8days before fertilization & should be deeply covered with soil
3. Not recommended to use as seed fertilizer
Urea N46,Urea Prilled 46%,Urea Granular 46%,Urea 46 Granular
Hebei Woldi Trading Co.,LTD , https://www.woldiexport.com