Application of reactive power compensation in low voltage distribution network
Xu Shuang Ankerui Electric Co., Ltd., Shanghai Jiading 201801 I. Introduction Reactive power compensation is the use of reactive power compensation equipment to provide the necessary reactive power to increase the power factor of the system, reduce energy consumption and improve the voltage quality of the power grid. From the basic situation of reactive power consumption in power grids, it can be seen that all levels of networks and transmission and distribution equipment must consume a certain amount of reactive power, especially the low-voltage distribution network. The use of reactive power compensation technology to increase the power factor of low-voltage power grids and electrical equipment has become an important measure for energy-saving work (1). Two: The main factors affecting power factor Asynchronous motors and power transformers are the main devices that consume reactive power. The reactive power consumed by the asynchronous motor is composed of two parts: reactive power at no-load and reactive power at certain load. The main component of reactive power consumption of the transformer is that its no-load reactive power supply voltage outside the specified range will also affect the power factor. Therefore, it is necessary to seek some practical methods that can improve the power factor of the low-voltage power network so that the low-voltage network can achieve reactive local balance and achieve the effect of reducing energy consumption (2). Third, low voltage distribution network reactive power compensation method The main method to improve power factor is to use low-voltage reactive power compensation technology. There are three main methods that we usually use: random compensation, follower compensation, and tracking compensation (1). (1) Random compensation: Connect the low-voltage capacitor bank and the motor in parallel, and control, protect the device and the motor. The random compensation at the same time is suitable for compensating the reactive power consumption of the motor, mainly compensating the excitation and reactive power. And the configuration is convenient and flexible, without frequent adjustment of the compensation capacity. Less investment and easy installation. (2) With device compensation: The low-voltage capacitor is connected to the secondary side of the distribution transformer through low-voltage protection to compensate for the no-load reactive power compensation method of the distribution transformer. It can effectively compensate for no-load reactive power distribution. It is one of the most effective means to compensate for reactive power by restricting the base load of reactive power in rural networks and making this part reactive and on-site balanced, thereby increasing the utilization ratio of distribution transformers and reducing the reactive power loss. (3) Tracking compensation: refers to the compensation method of compensating the low-voltage capacitor bank on the 0.4KV bus of the large user with the reactive power compensation switching device as the control protection device. It is applicable to special distribution transformers above 100K VA. It can replace random and follow-up two compensation methods, and the compensation effect is good. Fourth, the choice of ARC power factor controller Ankerui's ARC power factor controller strictly complies with the requirements specified in professional standards such as DL/T597 "Low-Voltage Reactive Power Compensation Controller Ordering Specifications" and JB/T9663 "Low-Voltage Reactive Power Automatic Compensation Controller" and other professional standards. According to the low-voltage distribution network to track the need for compensation and load characteristics. In general, the controller can be selected from the following aspects: Table 1 Product Application model Load requirements Compensation method Switch Capacitor Compensation plan ARC-6/J ARC-8/J ARC-10/J ARC-12/J ARC-6/R ARC-8/R ARC-10/R ARC-12/R Three-phase balanced load; and the reactive power is relatively stable, and users who do not need frequent switching of capacitance compensation are required. Single-load (high-power motor) on-site compensation and low-voltage switchgear centralized compensation Contactor Self-healing power capacitor Three-phase total compensation ARC-12F-J ARC-16F-J Three-phase balanced load; and the reactive power is relatively stable, and users who do not need frequent switching of capacitance compensation are required. Single-load (high-power motor) on-site compensation and low-voltage switchgear centralized compensation Contactor Self-healing capacitor Three-phase total compensation, sub-supplement ARC-12F-J ARC-16F-J Three-phase balanced load, or three-phase unbalanced load, variable load, impact load. Single-load (high-power motor) on-site compensation and low-voltage switchgear centralized compensation Capacitive non-contact switching switch Self-healing power capacitor Three-phase total compensation, sub-supplement Table 2 Product Selection Product number Function selection table Static output Dynamic output Overvoltage Undervoltage Overcurrent Under current Temperature protection Phase protection Harmonic protection communication Encoding ARC-6/J √ √ √ √ √ √ ARC-6/R √ ARC-8/J √ √ √ √ √ √ ARC-8/R √ ARC-10/J √ √ √ √ √ √ ARC-10R √ ARC-12/J √ √ √ √ √ √ ARC-12/R √ ARC-12F-J √ √ √ √ √ can selected √ √ Optional √ ARC-12F-R √ ARC-16F-J √ √ √ √ √ can selected √ √ Optional √ ARC-16F-R √ Fifth, reactive power compensation capacity selection method When the reactive power compensation capacity is mainly for the purpose of increasing the power factor, the choice of compensation capacity is divided into two major categories, namely, the selection of single-load local compensation capacity (mainly motor) and the selection of multi-load compensation capacity (referring to centralized and local grouping). make up) . 5.1 Selection of Local Load Compensation Capacity for Single Load (1) US data recommendation: Q c = ( 1/3) P e (1/3 of rated capacity) (2) Empirical coefficient method: Since the number of motor poles is different, the capacitor with a capacity closer to the actual need is determined by determining the empirical coefficient of the number of poles. When this method is generally used at 70% load, the post-compensation power factor may be 0.95 to 0.97. between. Table 3 Empirical coefficient method 5.2 Selection of Multiple Load Compensation Capacity The selection of multi-load compensation capacity is determined based on the power factor before and after compensation. Reactive power compensation capacity Qc is as follows: VI. Benefits of reactive power compensation Ankerui's controllers installed reactive power compensation devices on the side of the low-voltage line distribution cabinet of Jiangyin Metallurgical Co., Ltd. From the results of post-installation tests, the average current is reduced by 40 (A). The motor power factor is from The increase of 0.5 to 0.95 has reduced the consumption of the company's internal low-voltage power grid. The monthly electricity bill has been reduced from 12,000 yuan/month to 8,000 yuan/month, achieving the purpose of saving electricity. Due to the reduced input of reactive power in the grid, the metallurgical company benefits. references: [1] Ankerui Electric Co., Ltd. Product Selection Guide 2013.1. [2] Selection and Significance of Reactive Power Compensation Applied to Low-voltage Netting Towels Dongtian City, Shandong Province, Administration Square, Ai Tianpeng About the Author: Xu Shuang, female, undergraduate, Ankerui Electric Co., Ltd., the main research direction is reactive power compensation and active filter device design; Email: Mobile QQ Turbine High Speed Spiral hard Door
Hard turbine speed door: set energy-saving insulation and efficient wind environmental seal in a new metal industrial doors , opening speed of up to 1.5meters per second , For applications that require frequent rapid opening of the logistics channel , Insulation thickness 0.7mm aluminum door intermediate polyurethane foam , total thickness 40mm door wide 185mm per meter weight 1.63KG, Having good thermal insulation and light weight impact strength and other characteristics , wind rating of greater than 12 and theft , The door is suitable for indoor and outdoor fast-track logistics and production , The door type for enterprises save a lot of energy due to air flow generated loss than ordinary industrial sliding doors shutter doors save energy about eighty percent , Rapid opening and closing of the door so that enterprises in the rotational speed of the production and logistics of the door is greatly improved enterprise logistics and production must pass through the channel selection and its use is directly related to the efficiency of production and logistics , This product has high reliability , practicality and easy operation and quick fix for me , Drive control using a stable energy-effcient and accurate hard to guarantee fast and reliable operation of the door system the door to ensure trouble-free operation every year more than 250,000 times
High Speed Spiral Doors, fast opening garage doors, high speed garage doors, high speed metal doors, high speed aluminum doors SHENZHEN HONGFA AUTOMATIC DOOR CO., LTD , https://www.hongfafd.com